Stress-Strain Behavior of Confined Concrete during Cooling after Heating to High Temperature
Mahesh Gaikwad1, 2, Aparna Chaturvedi1, 2 and Suvir Singh1, 2
Full-Text PDF
XML 117 Views
DOI:10.17265/1934-7359/2025.03.003
1. Fire Safety Engineering, CSIR-Central Building Research Institute (CSIR-CBRI), Roorkee 247667 India
2. Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
Confined concrete, stress-strain relationship, elevated temperature, heating and cooling, fire.
Journal of Civil Engineering and Architecture 19 (2025) 130-136
doi: 10.17265/1934-7359/2025.03.003
[1] Abrams, M. 1973. “Compressive Strength of Concrete at Temperatures at 1600F.” In Bulletin RD016.01T. Illinois, USA: Portland Cement Association.
[2] Lie, T. T. 1992. Structural Fire Protection. ASCE Committee on Fire Protection. ASCE Manuals and Reports on Engineering Practice No. 78. New York, USA: American Society of Civil Engineers (ASCE).
[3] Youssef, M. A., and Moftah, M. 2007. “General Stress-Strain Relationship for Concrete at Elevated Temperatures.” Engineering Structures 29 (10): 2618-34.
[4] Dotreppe, J. C., Franssen, J., Bruls, A., Baus, R., Vandevelde, P., Minne, R., and van Nieuwenburg, H. L. 1997. “Experimental Research on Determining the Main Parameters Affecting the Behaviour of Reinforced Concrete Columns under Fire Conditions.” Mag. Concr. Res. 149 (6): 117-27.
[5] Mohamed, G., and Salah, D. M. 2012. “Analysis of Collapse for Concrete Columns during and after the Cooling Phase of a Fire.” In Proceedings of the XXX e Recontres AUGC-IBPSA, Chambery, Savoie, France, June 6-8, 2012.
[6] Salah, D. M., Guenfoud, M., Gernay, T., and Franssen, J. M. 2011. “Collapse of Concrete Columns during and after the Cooling Phase of a Fire.” Journal of Fire Protection Engineering 21 (11): 245-63.
[7] Gernay, T., Franssen, J. M., Robert, F., McNamee, R., Felicetti, R., Bamonte, P., Brunkhorst, S., Mohaine, S., and Zehfuß, J. 2022. “Experimental Investigation of Structural Failure during the Cooling Phase of a Fire: Concrete Columns.” Fire Safety Journal 134 (12): 103691.
[8] Gaikwad, M., Singh, S., Gopalakrishnan, N., Bhargava, P., and Chourasia, A. 2024. “Numerical Analysis of Fire-Exposed Reinforced Concrete Sections for Assessing Post-heating Axial and Flexural Capacity.” Journal of Structural Fire Engineering 15 (4): 557-81.
[9] Eurocode 2. 2004. Design of Concrete Structures: Part 1-2: General Rules—Structural Fire Design. Brussels, Belgium: European Committee for Standardization.
[10] Li, L. Y., and Purkiss, J. 2005. “Stress-Strain Constitutive Equations of Concrete Material at Elevated Temperatures.” Fire Safety Journal 40 (10): 669-86.
[11] Zaidi, K. A., Sharma, U. K., and Bhandari, N. M. 2012. “Effect of Temperature on Uni-axial Compressive Behavior of Confined Concrete.” Fire Safety Journal 48 (2): 58-68.
[12] Xiao, J., Li, Z., Xie, Q., and Shen, L. 2016. “Effect of Strain Rate on Compressive Behaviour of High-Strength Concrete after Exposure to Elevated Temperatures.” Fire Safety Journal 83 (7): 25-37.
[13] Eurocode 4. 1992. Design of Composite Steel and Concrete Structures Part 1.1 General Rules and Rules for Buildings. Brussels: CEN-European Committee for Standardization.
[14] Park, R., Priestley, M. N., and Gill, W. D. 1982. “Ductility of Square-Confined Concrete Columns.” Journal of the Structural Division 108 (4): 929-50.
[15] Sheikh, S. A., and Uzumeri, S. M. 1982. “Analytical Model for Concrete Confinement in Tied Columns.” Journal of the Structural Division 108 (12): 2703-22.
[16] Mander, J. B., Priestley, M. J. N., and Park, R. 1988. “Observed Stress-Strain Behavior of Confined Concrete.” Journal of Structural Engineering 114 (8): 1827-49.
[17] Mander, J. B., Priestley, M. J., and Park, R. 1988. “Theoretical Stress-Strain Model for Confined Concrete.” Journal of Structural Engineering 114 (8): 1804-26.
[18] Chang, Y. F., Chen Y. H., Sheu, M. S., and Yao, G. C. 2006. “Residual Stress-Strain Relationship for Concrete after Exposure to High Temperatures.” Cement and Concrete Research 36 (5): 1999-2005.
[19] Tao, Z., Wang, X. Q., and Uy, B. 2013. “Stress-Strain Curves of Structural Steel and Reinforcing Steel after Exposure to Elevated Temperatures.” Journal of Materials in Civil Engineering 25 (9): 1306-16.
[20] El-Fitiany, S. F., and Youssef, M. A. 2017. “Fire Performance of Reinforced Concrete Frames Using Sectional Analysis.” Engineering Structures 142 (7): 165-81.
[21] Gaikwad, M., Gopalakrishnan, N., Singh, S., and Bhargava, P. 2023. “Non-dimensional Interaction Curve for Fire-Exposed Reinforced Concrete Section.” Journal of Structural Engineering 49 (6): 407-17.